Improving thermal performance of water bath heaters in

Improving thermal performance of water bath heaters in

In this gas station, the water bath heater is located to heat up a maximum of 1000 m 3 /hr natural gas at nominal load. The inlet pressure in normal condition is 50 bar (5000 kPa) and the outlet pressure should be 16 bar (1600 kPa) [20] .

Method of natural gas pressure reduction on the city gate

Method of natural gas pressure reduction on the city gate

  A method of natural gas pressure reduction at a City Gate station providing an elimination of the station's energy consumption for gas flow heating together with the creation of a cooling duty for further utilization which comprises connecting a vortex tube inlet with a gas flow line for applying the whole gas flow entering the City Gate, connecting a cold fraction gas flow outlet from the

Natural Gas Portable Heater MH 0150 NM10 Mi T M

Natural Gas Portable Heater MH 0150 NM10 Mi T M

Congratulations on the purchase of your new Mi T M® Natural Gas Portable Heater! You can be assured your Mi T M® Natural Gas Portable Heater was constructed with the highest level of precision and accuracy. Each component has been rigorously tested by technicians to ensure the quality, endurance and perfor mance of this heater.

Study of Preheating Natural Gas in Gas Pressure Reduction

Study of Preheating Natural Gas in Gas Pressure Reduction

Gas pressure reduction station has built to reduce gas pressure. Process of passing through regulator lead to forming hydrated and pipe obstruction. Indirect water bath heater is a common device to heat natural gas before regulation. Most of thermal energy generated in burner of these heaters wasted by flue gas

Self Heating Pressure Reducer Gas Decompression CNG

Self Heating Pressure Reducer Gas Decompression CNG

VPRS Vortex Pressure Reduction Stations for Pipeline Natural Gas and CNG. A proprietary CNG decompression process (Vortex PRS_CNG) allows for complete elimination of high pressure gas preheat and raises the pressure regulated gas temperature also without applying any external man made energy.

Virginia Natural Gas

Virginia Natural Gas

Virginia Natural Gas operates and maintains natural gas pipes, reads meters and distributes natural gas to certified marketers, who sell it to more than 275,000 customers in southeastern Virginia.

GAS SUPPLY DESIGN GUIDE Home AERCO

GAS SUPPLY DESIGN GUIDE Home AERCO

AERCO Innovation and Reconseries heater s require a stable natural gas (all units) and propane (Innovation only) input pressure. The nominal inlet supply pressure to the heater is 7.0” W.C. The allowable natural gas inlet pressure range is 4.0” W.C. (min.) to 14.0” W.C. (max.) when firing at maximum input. For

Efficiency and heat losses of indirect water bath heater

Efficiency and heat losses of indirect water bath heater

At present, water bath heater is widespread used for gas industry to heat the natural gas. Its large size, the need for water reposition, its low thermal efficiency and large

Vortex Pilot Gas Heater Universal Vortex Inc

Vortex Pilot Gas Heater Universal Vortex Inc

Results: After installing a Dual Path Vortex Pilot Gas Heater at both Stations, UVI's client was able to shut down its line heaters during the summer months and reduce the gas discharge temperature to 0ºC (32ºF) in the winter time. The estimated savings for the client in fuel gas is $150,000/year.

Understanding Infrared Heaters AHRI

Understanding Infrared Heaters AHRI

or natural gas, and sometimes oil. the unit, heat either a steel tube (tube heater) or ceramic surface (luminous heater) within the heater. The heat from this surface is then emitted in the form of infrared radiant energy. Reflectors direct the infrared radiant energy downward to

Reducing energy consumption in Natural Gas Pressure Drop

Reducing energy consumption in Natural Gas Pressure Drop

liquid or solid phase condenses at the station exit. Indirect Water Bath Gas Heaters (known as line heater) are employed in the CGS to preheat the natural gas. The heaters are consuming a considerable amount of natural gas flowing though the CGS as fuel to provide the required heat for preheating the natural gas stream.

Natural Gas EXHEAT

Natural Gas EXHEAT

Natural Gas. Usually, a pressure reduction valve (PRV), ie a throttle valve (also known as Joule Thomson valve) is used at Pressure Reduction Stations (PRS) to reduce natural gas pressure before supply to a local gas distribution network. This pressure reduction in a PRS by a throttle valve results in reduction of both pressure and temperature of natural gas.

Natural Gas Preheaters Wattco

Natural Gas Preheaters Wattco

The natural gas preheaters are generally designed to prevent the Joule Thompson effect using Electrical Block Type Process Heaters. It is an indirect heater with aluminum encased block protected by stainless steel or carbon shell. It is called heat exchangers and is one of the best methods to heat up the natural gas before transmission.

Journal of Natural Gas Science and Engineering

Journal of Natural Gas Science and Engineering

Heater gas consumption Natural gas Temperature controller abstract Some stations in the gas transportation system experience a decrease in natural gas (NG) pressure. The drop in pressure occurs in the regulators and causes the temperature to drop so that the gas must be preheated to prevent it

US6155051A Method of heating natural gas in a city gate

US6155051A Method of heating natural gas in a city gate

Natural gas from a main supply line 4 enters the City Gate station. The temperature of the gas in the main supply line 4 will vary depending upon the particular climate, but may be as low as approximately 35 degrees Fahrenheit. The natural gas from the main supply line 4 is directed into a heat exchanger 6.

Feasibility of employing solar energy in natural gas

Feasibility of employing solar energy in natural gas

the heating duty of the heater and to reduce the amount of fuel consumption. The proposition includes a modified design of an in use CGS to take advantage of freely available solar heat. Keywords: Natural gas, Natural gas pressure drop station, Line heater, Solar energy, Solar thermal storage List of symbols A c collector area, m 2

Natural Gas Solutions

Natural Gas Solutions

Look to Emerson for your Natural Gas Solutions Emerson Process Management is a division of Emerson Electric. Emerson (NYSE: EMR), a FORTUNE 500 company located in St. Louis, Missouri USA. Emerson Process Management is the leader in natural gas solutions and provides the best in class natural gas conditioning, metering, pressure regulating

Natural gas reducing and metering stations Gas

Natural gas reducing and metering stations Gas

Natural gas reducing and metering stations The aim of a pressure reducing skid is to regulate the NG outlet pressure to a setting value. One typical solution consists mainly of two reducing streams (2x100% capacity) with two regulators each: one is the main regulator and the other is

Indirect fired heaters Gas Smart Metering

Indirect fired heaters Gas Smart Metering

Gas heaters are fired with natural gas which will be supplied to the burner at a specific pressure thanks to a dedicated fuel gas pressure regulators complete of all the required safety devices and electrical heating on a dedicated line. Used in order to reduce the viscosity to ease the oil stream transportation.

Study of preheating natural gas in gas pressure reduction

Study of preheating natural gas in gas pressure reduction

The natural gas first passes through a heater for preheating before it enters the regulators. Because the CGS heaters consume large amounts of gas, any decrease in gas consumption provides

Commercial eF Series Ultra High Efficiency Gas Water Heater

Commercial eF Series Ultra High Efficiency Gas Water Heater

Commercial eF Series® Ultra High Efficiency Gas Water Heater Photo is of EF 60T 199E 3N The eF Series® Models feature: Thermal Efficiency up to 99.1%—Ultra High Efficiency results in less fuel consumption and greater hot water recovery. ICON HD™—Intelligent proven design combines temperature control,

LH Line Heater Process Heating Solutions

LH Line Heater Process Heating Solutions

The Cata Dyne™ Line Heater heats the gas stream using infrared radiant heat transfer, eliminating the use of burners, glycol fluid and high maintenance heat exchange systems. It is also used to condition fuel gas for natural gas fired turbines or engines, and for heating of gas and diluent streams in a variety of process applications.