Bonding and Grounding of Flammable Liquids Quick Tips

Bonding and Grounding of Flammable Liquids Quick Tips

NFPA addresses the need for bonding and grounding in NFPA 30, the Flammable and Combustible Code. In the 2015 edition of NFPA 30, Chapter 18 Part 5.2.2 states that a means must be provided to minimize the generation of static electricity when transferring flammable liquids.

CAN/ULC S660 08 Standard for Nonmetallic Underground

CAN/ULC S660 08 Standard for Nonmetallic Underground

This Standard sets forth minimum requirements for primary carrier, secondary containment, integral primary/secondary, normal vent and vapour recovery, nonmetallic pipe, fittings, and systems (products) intended for use underground for the distribution of petroleum base flammable and combustible liquids, alcohols, and alcohol blended fuels as identified in this document.

Recommended Fuel Piping Specification

Recommended Fuel Piping Specification

All pipe, fittings and penetration fittings are to be listed by Underwriters Laboratories UL971 and ULC/ORD C971 2005 for Nonmetallic Underground Piping for Flammable Liquids and approved for use for Normal Vent, Vapor Recovery and Product Piping. All piping shall meet

BP WIND ENERGY POLICIES AND PROCEDURES Flammable

BP WIND ENERGY POLICIES AND PROCEDURES Flammable

grounded dip pipe or grounded wire be in the liquid in the container while it is being filled. The filling rate should be minimized, especially if there is a filter in the line. Pumping of flammable liquids from drums into safety containers is faster and away from any flammable liquids storage/dispensing areas outside of an approved

Gasoline/Ethanol Blend Fuel Dispensing UL

Gasoline/Ethanol Blend Fuel Dispensing UL

Gasoline/Ethanol Blend Fuel Dispensing • Power operated flammable liquid dispensing devices (EWTV) are investigated in accordance with UL 87, the Standard for Safety for Power Operated Dispensing Devices for Petroleum Products, when used with ethanol concentrations of 10 percent or less (E10). Dispensing devices intended for use with

UL 971 Standard for Nonmetallic Underground Piping For

UL 971 Standard for Nonmetallic Underground Piping For

1 Scope. 1.1 These requirements cover primary carrier, secondary containment, integral primary/secondary containment, normal vent and vapor recovery, nonmetallic pipe, fittings, and systems (products) intended for use underground in the distribution of petroleum base flammable and combustible liquids, alcohols, and alcohol blended fuels as identified in this standard.

Flammable Liquid Pipe Assemblies Petroleum Dispensing Pipe

Flammable Liquid Pipe Assemblies Petroleum Dispensing Pipe

Flammable Liquid Pipe Assemblies Petroleum Dispensing Pipe , Find Complete Details about Flammable Liquid Pipe Assemblies Petroleum Dispensing Pipe,Dispenser Pipe,Petroleum Dispensing Pipe,Flammable Liquid Pipe from Supplier or Manufacturer Dongying Wanhe Rubber &

UL 567 Standard for Emergency Breakaway Fittings, Swivel

UL 567 Standard for Emergency Breakaway Fittings, Swivel

1.7 A hose assembly provided with an integral swivel connector for petroleum product service shall comply with the applicable requirements in the Standard for Hose and Hose Assemblies for Dispensing Flammable Liquids, UL 330.

UL Standard for Safety Hose and Hose Assemblies for

UL Standard for Safety Hose and Hose Assemblies for

UL Standard for Safety Hose and Hose Assemblies for Dispensing Flammable Liquids Includes all amendments and changes through Revision Page(s) , Febru . View Abstract except for locations inside the housings of dispensing devices complying with the Standard For Power Operated Dispensing Devices For Petroleum Products, UL 87.

UL Standard for Safety Emergency Breakaway Fittings

UL Standard for Safety Emergency Breakaway Fittings

  A hose assembly provided with an integral swivel connector for petroleum product service shall comply with the applicable requirements in the Standard for Hose and Hose Assemblies for Dispensing Flammable Liquids, UL 330.

LIQUEFIED PETROLEUM GAS NFPA

LIQUEFIED PETROLEUM GAS NFPA

LIQUEFIED PETROLEUM GAS LP Gas Hazards When LP Gas is stored under pressure it changes phases to a liquid. If there is a loss in pressure it may leak temporarily as a liquid before converting to a heavier than air gas. LP Gas is flammable at a wide range of concentra tions, and due to its physical properties it presents several unique hazards.

Static Electricity and Flammable Liquid Safety ASSP

Static Electricity and Flammable Liquid Safety ASSP

When dispensing flammable or combustible liquids care must always be taken to dissipate static electricity and minimize the potential for fire. Although a 5 gallon pail may be convenient and cheap, the open surface of the liquid could collect enough flammable vapors to be within the flammable

Flammable liquids. Occupational Safety and

Flammable liquids. Occupational Safety and

Location and arrangement of vents for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) or Category 4 flammable liquids. Vent pipes from tanks storing Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) or Category 4 flammable liquids shall terminate outside of the building and higher than

Generation and Control of Static Electricity

Generation and Control of Static Electricity

The most common generators of static electricity are processes involving flammable liquids. Static electricity is generated by liquids flowing through pipes, and in mixing, pouring, pumping, filtering, or agitating liquids. The rate of generation is influenced by the conductive of the liquids, the amount of turbulence in the liquid, the

UNDERGROUND PETROLEUM PIPING SYSTEMS

UNDERGROUND PETROLEUM PIPING SYSTEMS

UNDERGROUND PETROLEUM PIPING SYSTEMS New York State Department of One safety concern involves the connection of flexible pipelines to the dispenser. In the event of a fire, the pipe could melt immediately below the emergency shut off valve, increasing “Non metallic Underground Piping for Flammable Liquids.” Underwriters’

Flexible Flammable Liquid Hose, Flexible Flammable Liquid

Flexible Flammable Liquid Hose, Flexible Flammable Liquid

About 26% of these are rubber hoses. A wide variety of flexible flammable liquid hose options are available to you, such as free samples. There are 33 flexible flammable liquid hose suppliers, mainly located in Asia. The top supplying country is China (Mainland), which supply 100% of flexible flammable liquid hose respectively.

Flammable liquids. Occupational Safety and

Flammable liquids. Occupational Safety and

Vent pipes from tanks storing Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 ºF (37.8 ºC), shall be so located that the discharge point is outside of buildings, higher than the fill pipe opening, and not less than 12 feet ( m) above the adjacent ground level.

Transportation of Hazardous Liquids by Pipeline 49 CFR 195

Transportation of Hazardous Liquids by Pipeline 49 CFR 195

Petroleum product means flammable, toxic, or corrosive products obtained from distilling and processing of crude oil, unfinished oils, natural gas liquids, blend stocks and other miscellaneous hydrocarbon compounds. Pipe or line pipe means a tube, usually cylindrical, through which a hazardous liquid or carbon dioxide flows from one point to

North Carolina & International Fire Codes For Storage of

North Carolina & International Fire Codes For Storage of

For Storage of Flammable & Combustible Liquids At Bulk Petroleum Storage Dispensing Facilities Tim Laughlin, P.E. Revised Aug Fire codes and environmental regulations change constantly regarding the storage of Flammable & Combustible Liquids at Petroleum Marketeering Facilities. elements as a unit or may be an assembly of